Pour la documentation en FRANÇAIS, utilisez l’outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

6.2.1

Complete List of Changes in ARTEMiS 6.2.1

  • Fixed SSN solver gives NaN when there are many isolated subcircuits inside the SSN model in the form of floating transformer secondaries. (TT#7025)
  • Fixed deadtime was not supported for MMC-1P block. Added detection of cross-firing allowing new test capability. (TT#6964)
  • Added Resistance shunt with a cell capacitor to allow discharge for MMC-1P block. (TT#6963)
  • Modify documentation format to allow compatibility with RT-LAB documentation. (TT#6819)

6.2.0

Complete List of Changes in ARTEMiS 6.2.0

  • Improve memory management in SSN solver during the offline simulation. (TT#6772)
  • Fixed error in the mask of Asynchronous Machine p.u. Units with non-unity rotor turn ratio with Matlab 2010b. (TT#6763)
  • Added parallel mode to SSN solver. (TT#6727)
  • Added voltage measurement to the Wideband and Frequency line. (TT#6695)
  • Added support of MatLab R2011a. (TT#6660)
  • Added support of MatLab R2011b. (TT#6953)
  • Fixed Error in Asynchronous Machine p.u. Units with non-unity rotor turn ratio with Matlab 2010b and newer. (TT#6800)



  • No labels