The circuit model file has been loaded into the example project already, although the steps below can be used to reload the circuit model.  This is typically only necessary if the circuit has been modified.  For more information, please refer to How to Add a Circuit Model to the System Definition.

  • In the Configuration Tree, under Power Electronics Add-On, click Circuit Model.
  • In the configuration page, click to Browse for the Circuit Model File Path.
  • Select the model (.mdl) file at the Circuit Model File Path shown below. This automatically triggers a model update in the System Definition. 
  • Wait for the update to complete.
  • (optional) Click the Refresh button to see additional model information.
  • Click Save.

Circuit Model File Path: <Public Documents>\National Instruments\<NI VeriStand 20XX>\Examples\OPAL-RT\Power Electronics Add-On\PMSM VDQ Local Control\Circuit Model\PMSM_eHS_UB.mdl


Configuring the PMSM Model

In this example, the PMSM model and associated sensors have been pre-configured. For more information related to machine configuration, please refer to the PMSM BLDC Section. Explore the configuration of the machine by following the steps below.

  • In the Configuration Tree, expand Circuit Model >> Machines and click PMSM BLDC 1 to open the configuration page for the machine.
  • Observe the configured machine parameters. The Input Mapping subsection allows the outputs of the circuit model to be easily connected to the inputs of the machine.
  • In the Configuration tree, expand PMSM BLDC 1 and click Mechanical Model to view the mechanical model parameters.
  • Confirm that the parameter values match those in the table below.


Motor Configuration
Motor TypePMSM Constant Ld/Lq

Direct Inductance (H)

0.002984
Quadrature Inductance (H)0.004576
Permanent Magnetic Flux (Wb)0.25366
Phase A Resistance (Ohm)0.12
Phase B Resistance (Ohm)0.12
Phase C Resistance (Ohm)0.12
Pole Pairs3
Direct Quadrature Transform Angle OffsetAligned
Sample Time (s)1.2E-7
Mechanical Model Configuration
Viscous Damping0.3665
Static Friction0.0019
Inertia0.0167
Mechanical Model Mode (VeriStand Channel)1