Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

This page is populated with a list of the Analog Output channels available for the selected Hardware Configuration.   Map eHS Measurements, machine model outputs, and other simulated signals to each Analog Output channel to interact with external hardware.  Gain, offset, minimum and maximum saturation factors can also be applied to the signals before they are output.

...

Channel Name

Type

Units

Default Value

Description

AOXXInputVolts0V

The Analog Outputs section is populated with one AOXX custom device channel for each physical Analog Output channel available in the selected Hardware Configuration.

If the CPU (VeriStand) Source option is mapped to an Analog Output channel, the value of its corresponding AOXX custom device channel defines the magnitude of the voltage output on the physical channel. If the CPU (VeriStand) mapping option is unused, the value of the channel does not affect the Analog Outputs or the simulation.

AOXX Gain

Input
Gain

Signal Gain to apply to channel AO<XX>.

When Enable Gain and Offset as Channels is enabled, the Analog Outputs >> Advanced >> Gain section is populated with oneAOXX Gain channel for each Analog Output channel.  The default value of this channel is the value of the Gain parameter in the Analog Outputs Configuration Page.

AOXX OffsetInputVoltsOffset

DC Offset to apply to channel AO<XX>.

When Enable Gain and Offset as Channels is enabled, the Analog Outputs >> Advanced >> Offset section is populated with oneAOXX Offset channel for each Analog Output channel.  The default value of this channel is the value of the Offset parameter in the Analog Outputs Configuration Page.

...