PMSM Variable Parameter Model Settings | ||||
Name | Specifies the name of the machine model. | |||
Description | Specifies a description for the machine model. | |||
Motor Configuration | ||||
---|---|---|---|---|
Motor Type | Choose from one of the following types. The motor configuration parameters automatically populate depending on the selected Motor Type. | |||
Mechanical Model Parameters | ||||
Symbol | Units | Default | Description | |
Inertia | kgm2 | 1 | Moment of inertia of the electric motor. This value must be equal to or greater than 0. | |
Friction Coefficient | 0 | Friction coefficient of the electric motor. This value must be equal to or greater than 0. | ||
Temperature Correction Parameters | ||||
Symbol | Units | Default | Description | |
Coil Base Temperature | Tc-base | Kelvin | 200 | Base temperature of the motor coil. This value must be equal to or greater than 0. |
Coil Temperature Coefficient | kc | 1/Kelvin | 0 | Coefficient for temperature correction of the motor resistance. The material of the coil determines this value. |
Magnet Base Temperature | Tm-base | Kelvin | 200 | Base temperature of the motor magnet. This value must be equal to or greater than 0. |
Magnet Temperature Coefficient | km | 1/Kelvin | 0 | Coefficient for temperature correction of the magnet flux. The material of the magnet determines this value. |
Input Mapping Configuration | ||||
Use the Input Mapping Configuration to route signals to the Voltage Phase A, Voltage Phase B, and Voltage Phase C inputs of the machine model. Available routing options may vary depending on the selected Hardware Configuration. | ||||
Group | Specifies the group that will be routed to the input voltages of the machine. The available routing options are defined by the selected Hardware Configuration, however it is typical to see the following options by default:
| |||
Element | Specifies the index of the measurement in the group that has been selected as the input voltage of the machine. |
...