AC Induction Machine Model Settings | ||||
Name | Specifies the name of the machine model. | |||
Description | Specifies a description for the machine model. | |||
Motor Configuration | ||||
---|---|---|---|---|
Symbol | Units | Default | Description | |
Magnetizing Inductance | Lm | Henries | 0.0462 | Specifies the magnetizing inductance of the motor. |
Stator Leakage Inductance | Lls | Henries | 0.00194 | Stator winding leakage inductance. This value must be greater than 0. |
Rotor Leakage Inductance | Llr | Henries | 0.00245 | Rotor winding leakage inductance. This value must be greater than 0. |
Stator Resistance | Rs | Ohms | 0.896 | Stator winding resistance. This value must be greater than 0. |
Rotor Resistance | Rr | Ohms | 1.82 | Rotor winding resistance. This value must be greater than 0. |
Loop Time | Ts | Seconds | 9E-7 | Describes the timestep of the machine model. |
Pole Pairs | PP | 2 | Number of machine pole pairs. | |
Mechanical Model Parameters | ||||
Symbol | Units | Default | Description | |
Inertia | kgm2 | 0.000225 | Moment of inertia of the electric motor. This value must be equal to or greater than 0. | |
Friction Coefficient | 0 | Friction coefficient of the electric motor. This value must be equal to or greater than 0. | ||
Temperature Correction Parameters | ||||
Symbol | Units | Default | Description | |
Base Temperature | Tbase | Kelvin | 298.15 | Base temperature for the stator resistance and the rotor resistance. This value must be greater than 0. |
Stator Temperature Coefficient | ks | 1/Kelvin | 0.00393 | Coefficient for temperature correction of the stator resistance. This value must be greater than 0. |
Rotor Temperature Coefficient | kr | 1/Kelvin | 0.00393 | Coefficient for temperature correction of the rotor resistance. This value must be greater than 0. |
Input Mapping Configuration | ||||
Use the Input Mapping Configuration to route signals to the Voltage Phase A, Voltage Phase B, and Voltage Phase C inputs of the machine model. Available routing options may vary depending on the selected Hardware Configuration. | ||||
Group | Specifies the group that will be routed to the input voltages of the machine. The available routing options are defined by the selected Hardware Configuration, however it is typical to see the following options by default:
| |||
Element | Specifies the index of the measurement in the group that has been selected as the input voltage of the machine. |
...