The OP5650 simulator offers quick, single-ended connections, through RJ45 and mini BNC connectors, to any monitoring device (i.e. oscilloscope, etc.). These mini-BNC jacks let you monitor 4 channels individually. Simply follow these instructions:



Only connect RJ45 cables from the upper section (A) monitoring jacks to lower section monitoring panel (B, as shown).  Connecting any other cable or device may result in damage to the equipment.

The network cable must only be connected to the standard computer connector network jack (see OP5650 Front Connectors). DO NOT connect the network cable in any jack other than the jack intended for that purpose.



How to connect cables for monitoring

A. Connect one end of the RJ45 cable to the desired channels

B. Connect the other end of the RJ45 cable to the monitoring connector

C. The mini-BNC jacks each connect to one of the 4 channels of the RJ45 Connector (B). Connect a mini-BNC cable to each BNC jack corresponding to the channel to be monitored, and connect the other end of the cable to the monitoring device.  