OP7000 front connector panels

A: Power switch with LED

B: Carrier board (OP7220) interfaces:

LEDDescription
RedInsufficient power voltage for digital board
Blinking redInsufficient power voltage for analog board
Blinking orangeNo mezzanine upload
OrangeSanity signal absent
YellowAll statuses normal
Blinking yellowError in analog board even slot


C: Monitoring connectors: See OP7000 Installation and Configuration for instructions on using these connectors.

D: OP7161 Front interface providing, from top to bottom :

Position

LED

Description

1

Power

On (green) indicates that the unit is powered up.

2

Config

Green indicates that a user-defined configuration (bitstream) is running. Yellow indicates that the safe, default configuration (bitstream) is running. Flashing indicates the configuration is paused.

Off indicates that there is no configuration available..

3

Comm

On (green) indicates communication with the PC is in progress.

4

Model

On indicates model in use.

5

Sync

Green indicates Master synchronization in progress Yellow indicates Slave synchronization in progress

6

Fault

Red indicates a fault.

7

User-defined

 Green/Yellow