In this case the FMUs can be easily linked to the internal solver of ePHASORSIM by only adding a new tab to the Excel file for each type of FMUs. Therefore, the following steps must be taken:
For each GenUnit type in the network data, an Excel sheet should be created with the same name as the GenUnit. For example, the figure below shows two new tabs, GENROU and GENROU_EXST1, are added to the existing Excel. At each FMU tab multiple instances of the same FMU can be declared. For example in the figure below, there are 2 instances of GENROU in the corresponding tab which each of them has a unique name.
Note: There is no limits in the number of FMU instances, except the existing memory usage. |
The first row of the FMU tab is the header to define the ID of FMU, its connection point to the power system, and name of its parameters. The header must begin with two keywords “name” and “bus0”, and it is followed by all the required parameter names of the GenUnit, see the above figure as an example.
The following rows will contain the values for the corresponding parameters.
Note:
|