To run a simulation, the VeriStand project must be configured to point to the real time controller.  Please see the Hardware Requirements and Deployment Target Software Requirements for a list of supported real time controllers and operating systems.

  • Click the Configure.. button to open the VeriStand System Explorer
  • Click the Controller item in the System Definition tree to open the configuration menu
  • Under Target Specification, input the IP address of the real time target to be used to run the real-time simulation
  • Ensure that either PharLap or Linux x64 is selected as the Operating System (depending on the operating system of the real time controller)
  • If permissions are configured on your Real Time target, enter the credentials in the Username and Password fields.  National Instruments targets are programmed with the following credentials by default:

    Username
    : admin     Password: <blank>